All OS
Yes.
- Choose “On: Digital Out” from the SRC Mode drop-down in the Lynx Mixer Adapter page.
- An external clock source transmitting the desired sample rate needs to be connected to the Digital In of the LynxTWO/L22 card.
- Set the Sample Clock source in the Lynx Mixer to any valid choice other than Digital. In the “System Clock Rates” section of the Adapter page, the L/R Clock should reference the rate of the audio being played. The Digital In section should display the rate from your target clock source.
- Audio playing back through the card will be re-sampled on output to match the target sample rate.
|